Fire Range Of 12 Bore IOF Pump Action Gun?

Posts related to shotguns.
Post Reply
hellboyraden
Learning the ropes
Learning the ropes
Posts: 15
Joined: Thu Jan 14, 2010 7:55 pm
Location: india

Fire Range Of 12 Bore IOF Pump Action Gun?

Post by hellboyraden » Tue Jan 19, 2010 8:53 pm

can anyone tell me what is the fire range of indian ordnance 12 bore pump action gun..??

For Advertising mail webmaster
winnie_the_pooh
Veteran
Veteran
Posts: 1767
Joined: Fri Aug 21, 2009 1:49 pm

Re: Fire Range Of 12 Bore IOF Pump Action Gun?

Post by winnie_the_pooh » Tue Jan 19, 2010 9:15 pm

The same as a single barrel 12 ga shotgun with a 20" barrel.And no,it will not send a man flying into the air.

goodboy_mentor
Old Timer
Old Timer
Posts: 2928
Joined: Sun Dec 07, 2008 12:35 pm

Re: Fire Range Of 12 Bore IOF Pump Action Gun?

Post by goodboy_mentor » Wed Jan 20, 2010 12:11 am

12 bore pump action guns do not have choke(cylinder choke), hence percentage of shot in a 76 cm (30 in) circle at 37 m (40 yd) will be around 40, hence "effective" range for pellet shot can be said to be around 20 yd. For slugs, it should be around 40-50 yd, beyond that slug would still be dangerous, but will not be accurate. Ref:
http://en.wikipedia.org/wiki/Shotgun
http://www.chuckhawks.com/shotgun_chokes.htm
http://www.angelfire.com/tx/ShotGun/
http://en.wikipedia.org/wiki/Shotgun_slug
http://www.chuckhawks.com/shotgun_slugs.htm

hellboyraden
Learning the ropes
Learning the ropes
Posts: 15
Joined: Thu Jan 14, 2010 7:55 pm
Location: india

Re: Fire Range Of 12 Bore IOF Pump Action Gun?

Post by hellboyraden » Wed Jan 20, 2010 6:57 pm

thanks a lot.."goodboy_mentor"

DAN
On the way to nirvana
On the way to nirvana
Posts: 78
Joined: Fri Nov 20, 2009 11:03 pm

Re: Fire Range Of 12 Bore IOF Pump Action Gun?

Post by DAN » Wed Jan 20, 2010 7:33 pm

It would be really better if it had a screw in choke :cry: Right ?

User avatar
Vikram
We post a lot
We post a lot
Posts: 5108
Joined: Fri Jun 02, 2006 6:14 am
Location: Tbilisi,Georgia

Re: Fire Range Of 12 Bore IOF Pump Action Gun?

Post by Vikram » Wed Jan 20, 2010 10:12 pm

goodboy_mentor wrote:12 bore pump action guns do not have choke(cylinder choke)
Is this specific to IOF Pump-action guns?Or all pump-action shotguns? Thanks.


Best-
Vikram
It ain’t over ’til it’s over! "Rocky,Rocky,Rocky....."

goodboy_mentor
Old Timer
Old Timer
Posts: 2928
Joined: Sun Dec 07, 2008 12:35 pm

Re: Fire Range Of 12 Bore IOF Pump Action Gun?

Post by goodboy_mentor » Wed Jan 20, 2010 11:58 pm

Is this specific to IOF Pump-action guns?Or all pump-action shotguns? Thanks.
Thanks for pointing out, it is not just pump actions, generally all shot guns(including pump action) with 20" or less barrel length do not have inbuilt choke. Since IOF pump action has 20" barrel, it is very unlikely it will have a inbuilt choke. Needs to be confirmed by someone who has IOF pump action. Pump actions with barrels longer than 20" are generally found with inbuilt/detachable chokes just like SBBL/DBBls with barrels longer than 20".
http://en.wikipedia.org/wiki/Riot_shotgun
http://en.wikipedia.org/wiki/Combat_shotgun

MoA
Veteran
Veteran
Posts: 1644
Joined: Fri Apr 11, 2008 8:08 pm

Re: Fire Range Of 12 Bore IOF Pump Action Gun?

Post by MoA » Thu Jan 21, 2010 1:55 am

I shoot slugs out of my Pump Action Maverick to 100 Meters without an issue. Then again it has a rifled barrel.
:cheers:

TwoRivers
Veteran
Veteran
Posts: 1526
Joined: Tue Feb 26, 2008 1:11 pm
Location: Fairbanks, Alaska

Re: Fire Range Of 12 Bore IOF Pump Action Gun?

Post by TwoRivers » Thu Jan 21, 2010 10:44 am

Hellboy: Keep in mind, though, that "effective range" for a shotgun means enough pattern density to kill a flying bird, not actual range or ability to wound. Also, the larger the shot size, the farther it will carry and penetrate. Number 5 shot, for instance, will penetrate human skin at 300 meters. Choke will affect the pattern, not the velocity or actual range of individual pellets. Cheers.

Post Reply